CWX-15Q electric valve quick open close 3 seconds

CWX-15Q electric valve quick open close 3 seconds

Availability: Available on backorder Categories: , Tags: ,

Description

electric valveelectric valve

Features of CWX-15Q electric valve:

1. Super mini valve body

2. POM and Metal gear, lower the motor drive noise, which improve the reliability of the valve.

3. Long service life, nearly 50 thousands open-close times.

4. Combining electric limit and mechanical limit in design. In addition, it features precise positioning and high consistency to prevent the actuator from continuing to run even after reaching the position.

5. Actuator and valve body can installed muti-angle, therefore convenient for room allocation and application. 


Applying scenarios of CWX-15Q electric valve:

1.Such as water central heating system pipes network

2.For example auto control system for flow measurment

3.Such as home and business drinking water equipment

4. As well as air-conditioning fan coil(HVAC)

5. Besides, water save and purification equipment


Main Parameter of CWX-15Q electric valve:

Product modelCWX-15Q
Output torque1.5NM
Rated voltageDC3-6V
DC12V
AC/DC9-24V
AC220V
AC85-265V
Power<2W
Working current<100mA (CR04 except Max150mA)
Open/close time3S
Position IndicatorOptional (without by default)
Manual overrideNo
Gear MaterialPOM & metal gear
Working pressureMax1.0Mpa
Valve MaterialBrass
UPVC
Stainless Steel
Valve size2way DN8-DN25
3Way DN8-DN20
Control modeCR01,CR02,CR02+,CR03,CR03A,CR03T,CR04,CR05
Environment temperature0-50℃
Medium temperature0-90℃
IP GradeIP65
Feedback SignalUnable
Service Life Time50000 open-close times
SealingPTFE
Ball SeatRubber

Schematic & Dimension of CWX-15Q electric valve:

motorized water valve

BrassConnectionSized (mm)L  (mm)H  (mm)W  (kg)
Both female thread full port         DN8846310.287
DN151557380.363
DN202071450.444
DN2523.572490.533
Both female thread reduce portDN10846310.286
DN201566380.378
DN252072470.538
DN322586600.75
3-way verticalDN151263490.365
DN201566530.422
Female-male thread full portDN151563380.362
Female-male thread reduce portDN201566380.392
DN322076500.624
Both male threadDN151568380.354
Stainless steelBoth female thread full port         DN8846310.294
DN151555380.37
DN202071450.438
DN252572490.547
Both female thread reduce portDN1084630.50.298
DN201563390.443
DN252075470.538

Wiring Diagrams of CWX-15Q electric valve:

CR01(two wires and reverse polarity) Voltage: DC3-6V/DC12V/DC9-24V

electric valve

1.Connect SW to OPEN, then the valve open, getting the position and automatically power off, moreover the valve remains fully open position.
2.Connect SW to CLOSE, then the valve close, getting the position and automatically power off, moreover the valve remains fully closed position.

CR02 (three wires two wires control) Voltage: DC3-6V/DC9-24V

electric valve

1.Connect SW to OPEN, then the valve open, getting the position and automatically power off, moreover the valve remains fully open position.
2.Connect SW to CLOSE, then the valve close, getting the position and automatically power off, moreover the valve remains fully closed position.

CR03 (three wires one wire control) Voltage: DC3-6V/DC12V/DC9-24V/ADC9-24V/AC85-265V

electric valve

1.Connect SW, then the valve open, getting the position and automatically power off, moreover the valve remains fully open position.
2.Disconnect SW, then the valve close, getting the position and automatically power off, moreover the valve remains fully closed position.

CR04 (two wires and fail-safe/power-off return) Voltage: ADC9-24V/AC85-265V

electric valve

1.SW connect, then the valve open/close, getting the position and the power off automatically, moreover the valve remains fully open/close position.
2.SW disconnect, then the valve close/open, getting the position and power off automatically, moreover the valve remains fully close/open position.

CR05 (five wires, micro controller with feedback signal) Voltage: DC3-6V/DC12V/DC24V

electric valve

1.Connecting SW to OPEN, then valve open, getting the position and OLS connected, the controller tested and find the signal of AOLS, moreover the valve remains fully open position, mean while power off automatically.
2.Connecting SW and CLOSE , then valve close, getting the position and CLS connected, the controller tested and find the signal of ACLS, the valve remains fully close position, mean while power off automatically.





    has been added to your cart:
    Checkout