CWX-15N electric water valve central heating diverter valve
- Description
- Inquiry
Description
Features of CWX-15N electric water valve central heating diverter valve:
1. Super mini and compact valve body, thus space-saving installation.
2. POM and Metal gear, lower the motor drive noise, so that improve the reliability of the valve.
3. Long service life, especially nearly 50 thousands open-close times.
4. Combining electric limit and mechanical limit in design. In addition, it features precise positioning and high consistency to prevent the actuator from continuing to run even after reaching the position.
5. Actuator and valve body can installed muti-angle, so that convenient for room allocation and application.
Applying scenarios of CWX-15N electric water valve central heating diverter valve:
1. Especially water central heating system pipes network
2. Also Auto control system for flow measurment
3. As well as home and business drinking water equipment
4. Such as air-conditioning fan coil(HVAC)
5. Water save and purification equipment
Main Parameter of CWX-15N electric water valve central heating diverter valve:
Product model | CWX-15N |
Output torque | 2NM |
Rated voltage | DC3-6V, DC12V, AC/DC9-24V, AC220V, AC85-265V |
Power | <2W |
Working current | <100mA (CR04 except Max150mA) |
Open/close time | 5S |
Position Indicator | yes (without by default) |
Manual override | No |
Gear Material | POM & metal gear |
Working pressure | Max1.0Mpa |
Valve Material | Brass, UPVC, Stainless Steel |
Valve size | Max DN32 2way DN8-DN25 3Way DN8-DN25 Reduce Port DN25 or smaller |
Control mode | CR01, CR02, CR02+, CR03, CR03A, CR03T, CR04, CR05 |
Environment temperature | 0-50℃ |
Medium temperature | 0-90℃ |
IP Grade | IP65 |
Sealing | Rubber |
Seat | PTFE |
Schematic & Dimension of CWX-15N electric water valve central heating diverter valve:
Brass | Connection | Size | d (mm) | L (mm) | H (mm) | W (kg) |
Both female thread full port | DN8 | 8 | 46 | 31 | 0.287 | |
DN15 | 15 | 57 | 38 | 0.363 | ||
DN20 | 20 | 71 | 45 | 0.444 | ||
DN25 | 23.5 | 72 | 49 | 0.533 | ||
Both female thread reduce port | DN10 | 8 | 46 | 31 | 0.286 | |
DN20 | 15 | 66 | 38 | 0.378 | ||
DN25 | 20 | 72 | 47 | 0.538 | ||
DN32 | 25 | 86 | 60 | 0.75 | ||
3-way vertical | DN15 | 12 | 63 | 49 | 0.365 | |
DN20 | 15 | 66 | 53 | 0.422 | ||
Female-male thread full port | DN15 | 15 | 63 | 38 | 0.362 | |
Female-male thread reduce port | DN20 | 15 | 66 | 38 | 0.392 | |
DN32 | 20 | 76 | 50 | 0.624 | ||
Both male thread | DN15 | 15 | 68 | 38 | 0.354 | |
Stainless steel | Both female thread full port | DN8 | 8 | 46 | 31 | 0.294 |
DN15 | 15 | 55 | 38 | 0.37 | ||
DN20 | 20 | 71 | 45 | 0.438 | ||
DN25 | 25 | 72 | 49 | 0.547 | ||
Both female thread reduce port | DN10 | 8 | 46 | 30.5 | 0.298 | |
DN20 | 15 | 63 | 39 | 0.443 | ||
DN25 | 20 | 75 | 47 | 0.538 |
Wiring Diagrams of CWX-15N electric water valve central heating diverter valve:
CR01(two wires and reverse polarity) Voltage: DC3-6V/DC12V/DC9-24V
1.Connect SW to OPEN, then the valve open, getting the position and automatically power off, moreover the valve remains fully open position.
2.Connect SW to CLOSE, then the valve close, getting the position and automatically power off, moreover the valve remains fully closed position.
CR02 (three wires two wires control) Voltage: DC3-6V/DC9-24V
1.Connect SW to OPEN, then the valve open, getting the position and automatically power off, moreover the valve remains fully open position.
2.Connect SW to CLOSE, then the valve close, getting the position and automatically power off, moreover the valve remains fully closed position.
CR03 (three wires one wire control) Voltage: DC3-6V/DC12V/DC9-24V/ADC9-24V/AC85-265V
1.Connect SW, then the valve open, getting the position and automatically power off, moreover the valve remains fully open position.
2.Disconnect SW, then the valve close, getting the position and automatically power off, moreover the valve remains fully closed position.
CR04 (two wires and fail-safe/power-off return) Voltage: ADC9-24V/AC85-265V
1.SW connect, then the valve open/close, getting the position and the power off automatically, moreover the valve remains fully open/close position.
2.SW disconnect, then the valve close/open, getting the position and power off automatically, moreover the valve remains fully close/open position.
CR05 (five wires, micro controller with feedback signal) Voltage: DC3-6V/DC12V/DC24V
1.Connecting SW to OPEN, then valve open, getting the position and OLS connected, the controller tested and find the signal of AOLS, the valve remains fully open position, mean while power off automatically.
2.Connecting SW and CLOSE , then valve close, getting the position and CLS connected, the controller tested and find the signal of ACLS, the valve remains fully close position, mean while power off automatically.